1. Palette
Displays the highest and lowest temperature measurement values of the current
view. Tap to choose between dierent infrared temperature measurement palettes,
or enable the isotherm to set temperature measurement intervals. Note that if the
measured area exceeds the maximum or minimum temperature measurement values
of the current view, the setting will not take eect.
2. Gain Mode
3. SBS
The infrared screen is set as single infrared view by default. Tap to enable or disable
side-by-side view. When enabled, both the footage captured by the thermal camera
and the zoom camera will be displayed side by side.
4. FFC
Tap to start FFC calibration. FFC calibration is a function of the thermal camera that
optimizes image quality for easy observation of temperature changes.
5. Link Zoom
Tap to link the lenses of the thermal camera and zoom camera to zoom. The user can
view the linked zoom eect by enabling the SBS button in the thermal camera view.
6. Thermal Camera Zoom
• Tap on the screen or select an area to perform spot temperature measurement
or area temperature measurement.
DJI Matrice 4 Series User Manual
64 © 2025 DJI All Rights Reserved.