XR500 Series Canadian Programming Guide Digital Monitoring Products
25
SYSTEM REPORTS
7.14.1
REMOTE CHANGE IP
Remote Change IP
ThisoptiondisplayswhenNETisselectedforSendLocalChanges.EntertheIP
address containing up to 12 digits. The Net IP Address must be unique and cannot
be duplicated on the network. Enter all 12 digits and leave out the periods. For
example,enterIPaddress192.168.0.250as192168000250.Theperiodsdisplay
automatically. Default is 000.000.000.000
7.14.2
REMOTE CHANGE
Remote Change Port
ThisoptiondisplayswhenNETisselectedforSendLocalChanges.EnterthePort
number.Validnumbersarefrom0to65535.Defaultis2002.
7.14.3 Remote Telephone Number
ThisoptiondisplayswhenDDisselectedforSendLocalChanges.PressCOMMANDto
enter the phone number the panel dials when sending programming changes. After
enteringaphonenumber,thepanelsendsanypanelchangestoRemoteLink.
Thephonenumbercanhavetwolinesof16characterseachtoequal32.Entera
P to program a two second pause in the dialing sequence. The P character counts
aspartofthe32allowablecharacters.Enter*70Pasthestringrstcharactersto
cancel call waiting. Dial tone detect is an automatic panel function.
System Reports
8.1
SYSTEM REPORTS
System Reports
Selectspecicsystemreportsthepanelsendstothereceiver.
8.2
ABORT NO YES
Abort Report
YES allows the panel to send an alarm abort report to the receiver any time an area
is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff
Time has not expired. After disarming an area, if any other area remains armed and
haszone(s)inalarm,thealarmabortreportisnotsent.
If the communication type is set to DD, a Warning: Alarm Bell Silenced report is also
sent if the alarm bell is silenced.
Note: Abort Reports are not sent for Fire, Fire Verify, or Supervisory type zones.
8.3
RESTORAL: YES
Restoral Reports
This option allows you to control when and if a zone restoral report is sent to the
central station receiver. Press any Select key to display the following options:
NO YES DISARM
NO - Disables the zone restoral report option. Zones continue to operate normally
but do not send restoral reports to the receiver.
YES - Enables the zone restoral report option. Zone restorals are sent whenever a
zone restores from a trouble or alarm condition.
DISARM -Causesthepaneltosendrestoralreportsforanon-24-hourzonewhenever
azonethathasrestoredfromatroubleoralarmconditionisdisarmed.All24-hour
zones send restoral reports as they restore.
8.4
BYPASS NO YES
Bypass Reports
YES allows the panel to send all zone bypasses, resets, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
name and number of the individual operating the system. Reports are only sent if
O/CUserinCommunicationsissetYESforReceiver1orReceiver2.
8.5
SCHD CHG NO YES
Schedule Change Reports
YES allows the panel to send all schedule changes to the receiver. The report
includes the day, opening time, closing time, extend schedule time, and the user
name and number of the individual making the change. Schedule changes made
throughRemoteLink™arenotsenttotheprinterorDisplayEvents.
000.000.000.000
PORT: 2002
REMOTE PHONE NO.
-
-

Table of Contents

Other manuals for DMP Electronics XR500 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR500 SERIES and is the answer not in the manual?

DMP Electronics XR500 SERIES Specifications

General IconGeneral
BrandDMP Electronics
ModelXR500 SERIES
CategoryControl Panel
LanguageEnglish

Related product manuals