APPENDIX
23.6 Cross Zoning
Caution must be taken when cross zoning devices
to ensure that the Cross Zone Time is long enough
to allow an intruder to trip both devices before it
expires. A Cross Zone Time that is too short may
allow an intruder to trip the devices and allow
only a zone fault report be sent to the central
station.
WhenaCrossZonedzonetripsaFAULTreport
issenttotheSCS-1RReceiver.WhentwoCross
Zoned zones trip within the Cross Zone Time, both
zonessendALARMsignalstothereceiver.For
example, if zones 1 and 2 are Cross Zoned zones,
andonlyzone1trips,aFAULTreportissentto
the receiver for zone 1. If zone 1 trips and zone 2
tripswithintheCrossZoneTime,anALARMreport
is sent to the receiver for zone 1 and zone 2.
23.7 Events Manager
The Events Manager allows you to delay sending certain reports to the central station receiver. Reports can
be kept in the panel memory until overwritten by new activity or held until the memory buffer reaches 50
events or 50 door access granted events. When the buffer is full, the panel automatically sends the stored
reports to the central station receiver. The table lists the panel reports you can delay using the Events
Manager option.
23.8 UserProles
Aproledenestheauthorityofeachusercodeinthesystem.ProlesareprogrammedintheKeypad
UserMenu.SeveralcharacteristicsassociatedwitheachUserProledeneitsauthoritywithinthe
system. To effectively program an XR500 Series system, you must understand the interrelationship
betweenproles,devices,outputgroups,andareas.BelowisabriefexplanationoftheUserProle
elements.Formoreinformationaboutuserproles,refertotheUserProlesRecordandtheXR100/
XR500User’sGuide(LT-0683).
Note:ProlescannotbechangedviakeypadinanAll/PerimeterorHome/Sleep/Awaysystem.Usethe
defaultproles1through10.
Prole Number-Eachprolemaybeassignedauniquenumberfrom1to99.
Prole Name-Eachprolemaybeassigneda32-charactername.TheProleNumberisthedefaultname.
Area Number -Eachprolemaybeassignedspecicareasofthesystemforarminganddisarming.
Whencreatingproles1to98,NOareasareassignedbydefault.Thedefaultforprole99isALLareas
assigned.Prole99ispreprogrammedinthesystematthefactory.
Access Area Number-Eachprolemaybeassigneddooraccessareaassignments.Defaultforprole1to98
isNOareasassigned.Defaultforprole99isALLareasassigned.Prole99ispreprogrammedatthefactory.
Output Group Assignment-Eachprolemaybeassignedanoutputgroupnumberfrom1to10.Default
forprole1to98isNOoutputgroupassigned.Defaultforprole99isoutputgroup10. Your system may
by programmed to turn on an output group at certain keypads when door access occurs.
User Menu Assignments-Eachuserprolemayhaveanyofthemenusassignedtoitasshowninthe
followingUserProleRecord.TheUserProleRecordliststheusermenuproleassignmentsandthe
systemfunctionsusersareallowedtoaccessbasedontheprolenumbersassignedtotheircodes.
Alwaysmakesurethatatleastoneadministratorinyoursystemhasaprolewithall authorities and
areas.
Report Type Immediately Delayed
Alarm Y
Trouble Y
Restore Y
Opening Y
Closing Y
Bypass Y
Reset Y
Supervisory Y
Add Codes Y
Delete Codes Y
Change Codes Y
Permanent Schedule Change Y
Temporary Schedule Change Y
Door Access Y
Door Access Denied Y
Late to Close Y
Force Armed Zone Y