XT Series Programming Guide Digital Monitoring Products, Inc.
9
COMMUNICATION
3.19 First Telephone Number
Enter the rst number the panel dials to send reports to this receiver. A phone
number may contain two lines of 16 characters to equal 32 characters. You can
program a three-second pause in the dial ing se quence by en tering P. Program a
dial tone detect by entering D. These characters are counted as part of the 32
characters.
Call Waiting: You can place the “* 7 0 P” (Star, Seven, Zero, Pause) in the telephone
number rst position to cancel Call Waiting. For example, program NET with second
line DD and phone number *70P555-1212, and you have NET with Call Waiting
cancelled on the second line.
Caution: A call waiting cancel programmed on a non-call waiting telephone line
would prevent communication to the central station.
3.20 Second Telephone Number
The panel dials the second number after two successive attempts failed using the
rst number. If the panel cannot reach this receiver after two attempts using the
second number, it returns to the rst number and makes two additional attempts. A
total of ten dialing attempts are made using the rst and second phone num bers. If
a second phone number is not entered, the rst phone number is used for all dialing
attempts. Each number can be up two lines of 16 characters to equal 32 characters
in length, in cluding any P, D, or *70P char acters entered for pause, dial tone detect,
or call waiting cancel option.
3.21 First IP Address
Enter the rst (primary) IP address where the panel sends network or cell messages.
The IP address must be unique and cannot be duplicated on the network. Enter all
12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
For NET: The rst and second IP addresses are alternately used for 8-second
intervals until successful communication or 1 minute elapses.
For Cell: The message is sent using First GPRS APN and the First IP Address. If
no acknowledgment is received, First GPRS APN and the Second IP address are
used, followed, if needed, by Second GPRS APN and rst and second IP addresses,
respectively.
3.22 First IP Port
Enter the rst IP port number to be used in conjunction with the First IP Address.
The IP port identies the port used to communicate messages to and from the
panel. The default IP Port setting is 2001.
3.23 Second IP Address
Enter the second IP address where the panel sends network messages. The IP
Address must be unique and cannot be duplicated on the network. Enter all 12
digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
3.24 Second IP Port
Enter the second IP port number to be used in conjunction with the Second IP
Address. The IP port identies the port used to communicate messages to and from
the panel. The default IP Port setting is 2001.
3.25 Receiver 2 Programming
Allows you to set the options for the second receiver the XT30/XT50 panel attempts
to contact when sending reports. The XT30/XT50 supports communication to two
receivers. If you select YES for any of the Receiver 2 options, you must have at least
one phone number or IP address programmed in Receiver 2 programming. Receiver 2
defaults are set to NO.
3.26 Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error,
and System Recently Armed reports to be sent to this receiver. Default is NO.
-
-
FIRST PHONE NO.
-
-
SECOND PHONE NO.
FIRST IP ADDR
000.000.000.000
FIRST IP PORT
2001
SECOND IP ADDR
000.000.000.000
SECOND IP PORT
2001
RECEIVER 2 PROG
ALARM NO YES

Table of Contents

Other manuals for DMP Electronics XT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XT Series and is the answer not in the manual?

DMP Electronics XT Series Specifications

General IconGeneral
BrandDMP Electronics
ModelXT Series
CategoryControl Panel
LanguageEnglish

Related product manuals