Digital Monitoring Products, Inc. XT Series Programming Guide
14
MESSAGING SETUP
5.10 Email Communication Type
Choosing NET sends Email messages over the network. Choosing CELL sends Email
messages via cellular communication. Default is NET. This option appears only if
any destination above is an e-mail address and the panel is a network panel (has an
Ethernet connector). If the panel is not a network panel the Email must be sent
by CELL.
5.11 O/C Email
Select YES to allow the panel to send Opening and Closing reports via Email. Default
is NO. This option appears only if any destination above is an Email address.
5.12 O/C SMS
Select YES to allow the panel to send Opening and Closing messages to a cell phone
via SMS protocol. Default is NO. This option appears only if any destination above is
a cell phone number.
5.13 Monthly Limit
This option displays if any programmed destination is a cell phone number or an
Email address. This number limits the monthly incoming and outgoing SMS messages
allowed to be sent or received by the panel.
A panel event that causes messages to be sent to destination cell phone numbers
or destination Email addresses is counted towards the panel’s monthly limit. For
example, if an alarm message is sent to a cell phone number and an Email address,
a total of 2 messages are counted towards the monthly limit for the panel. SMS
messages sent from a cell phone to the panel, including status requests and
MyAccess™ text messaging commands, also count toward the monthly limit. The
limit is reset at midnight on the 14th of every month. Range is from 0 to 999.
When 0 is entered, there is no limit on the number of messages able to be sent or
received by the panel. Default is 0.
Note: The SecureCom Wireless text plan selected for the panel should match or
exceed the programmed Monthly Limit.
The remaining options will only appear if Email messaging has been selected to be
sent via network. The options allow the Email server to be selected by the installing
dealer. Typically this will be the Email service provided by the installing dealer. This
allows opportunity for additional services to be provided to the end user.
5.14 SMTP Server
Enter the SMTP (Simple Mail Transfer Protocol) Server name. The SMTP Email server
is responsible for sending the Email to its destination. An example SMTP Email
server name is: mail.somedomain.com. The domain should be the Email server that
will provide Email support for your alarm customers.
5.15 SMTP Server Port
The SMTP server port number is the port that the panel uses to initiate a TCP
connection with the Email server. The default port is 25.
5.16 SMTP Username
Most SMTP servers require a username to send Email. This will be sent to the SMTP
server in conjunction with the SMTP Password to provide Email authentication to
the server.
5.17 SMTP Password
Most SMTP servers require a password to send Email. This will be sent to the SMTP
server in conjunction with the SMTP Username to provide Email authentication to
the server.
5.18 From Email Address
Enter the Email address on le with the Email service. This will show up in the Email
messages as the sender’s address.
EMAIL COMM TYPE
NET CELL
O/C EMAIL NO YES
O/C SMS NO YES
MONTHLY LIMIT: 0
SMTP SERVER
-
SMTP PORT: 25
SMTP USERNAME
-
SMTP PASSWORD
-
FROM EMAIL
-

Table of Contents

Other manuals for DMP Electronics XT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XT Series and is the answer not in the manual?

DMP Electronics XT Series Specifications

General IconGeneral
BrandDMP Electronics
ModelXT Series
CategoryControl Panel
LanguageEnglish

Related product manuals