XT Series Programming Guide Digital Monitoring Products, Inc.
17
REMOTE OPTIONS
If an alarm occurs during a remote connect, the panel disconnects from the service
receiver and calls the alarm receiver. Alarm reports are only sent to the alarm
receiver. It is important that the alarm receiver key and the service receiver key
programmed at the central station are NOT the same so the panel can determine
the difference between receivers.
When NO is selected, remote commands and programming are not accepted from a
secondary service receiver.
7.8 Remote Disarm
Enter YES to enable the panel to be disarmed remotely. Selecting NO disables
remote disarming.
7.9 App Key
Enter the 8-digit App Key obtained in your Dealer Settings tab at
vk.securecomwireless.com.
This option is a security feature of the Virtual Keypad iPhone/Android App used only
when your Dealer Settings at vk.securecomwireless.com have “EASYconnect” set as
the Communication Type.
This communication option is only available for XT panels with onboard network
and is used to eliminate the need for a static IP address programmed in Network
Options.
To enter a new App Key, press any select key or area and enter any combination of
8 digits.
Press COMMAND. The default for this option is blank.
System Reports
8.1 System Reports
This function allows you to select the reports the XT30/XT50 sends to the receiver.
8.2 Opening/Closing Reports
NO - No Opening/Closing Reports are sent.
YES - Sends Opening/Closing Reports for each programmed area.
8.3 Abort Reports
YES allows the panel to send an Alarm Abort Report to the receiver any time an area
is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff
Time has not expired. See the Bell Cutoff section. The area must be disarmed and
no alarmed zones can still be armed.
YES also allows a Bell Silenced Report to be sent if the alarm bell is silenced with
a valid user code during an alarm, if the communication type is not CID. Default is
NO.
Note: Alarm Cancel or Verify Reports are sent if the alarm is canceled or veried
after being sent to the alarm receiver, if the Bell Cutoff timer has not expired. The
Abort Reports option does not affect Cancel or Verify reports.
The panel will not send Abort reports for Fire zones, Fire Verify, or Supervisory-type
zones.
8.4 Zone Restoral Reports
This option allows you to specify whether the panel sends zone restoral reports and
also when they will be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores
from an alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from
an alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
8.5 Bypass Reports
YES allows the panel to send all zone bypass, reset, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
number of the individual bypassing the zone.
DISARM NO YES
APP KEY:
SYSTEM REPORTS
O/C RPTS NO YES
ABORT NO YES
RESTORAL YES
NO YES DISARM
BYPASS NO YES
SYSTEM REPORTS

Table of Contents

Other manuals for DMP Electronics XT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XT Series and is the answer not in the manual?

DMP Electronics XT Series Specifications

General IconGeneral
BrandDMP Electronics
ModelXT Series
CategoryControl Panel
LanguageEnglish

Related product manuals