Digital Monitoring Products, Inc. XT Series Programming Guide
18
SYSTEM REPORTS
8.6 Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user number added or deleted and
the user number of the individual making the change.
8.7 Ambush
YES allows an ambush report to be sent any time user code number one is entered
at a keypad. Selecting NO disables the ambush report and allows user code number
one to operate the same as all other codes.
8.8 Late To Open
Enter 1-240 as the number of minutes to elapse that the system may remain armed
after the opening time of a schedule without sending a Late To Open message. If
the system continues to be armed after the Late to Open minutes expire, a Late To
Open message is sent to the central station. Default is 0, which disables the Late To
Open option.
8.9 Early To Close
Enter 1-240 as the number of minutes that the system can be armed prior to the
scheduled closing time. If the system is armed prior to the Early to Close minutes,
an Early To Close message is sent to the central station. Default is 0, which disables
the Early to Close option.
System Options
9.1 System Options
This section allows you to select system wide parameters used in the operation of
the XT30/XT50 system. A description of each System Option follows:
9.2 System
This congures the panel as either a six Area system, an All/Perimeter system
(Perimeter/Interior), or a Home/Away system (Perimeter, Interior, and Bedrooms).
Zones must be assigned to Bedrooms for the area to be active.
When using wireless zones for an Area or All/Perimeter system, the keypad trouble
buzzer resounds every four hours when wireless zone trouble or wireless low battery
is displayed.
9.3 Closing Code
When YES is selected, a code number is required for system arming. If NO is
selected, a code number is not required for system arming. Default is NO.
9.4 Closing Check
Select YES to enable the panel to verify that all areas have been armed after a
schedule expires. If the Closing Check nds any areas disarmed past the scheduled
time, all keypads emit a steady beep and display CLOSING TIME!. The user must
extend the schedule or arm the system within 10 minutes or a Late to Close
message will be sent to the central station. Default is NO.
9.5 Entry Delay 1
Enter the entry delay time for all exit type zones programmed to use Entry Delay 1.
When an armed Exit type zone is faulted, the keypad prewarn tone begins sounding.
ENTER CODE: - and the name of the zone causing the Entry Delay displays on
all keypads.
When the rst digit of a code is entered, the prewarn tone stops at the keypad.
If, within ve seconds, a valid user code is not entered or an invalid user code is
entered, the prewarn tone begins sounding again. Fifteen seconds must elapse
before entering a digit silences the prewarn tone again.
The area must be disarmed before the entry delay expires or an alarm will be
detected. All Burglary type zones in all areas are delayed along with the Exit zone.
Entry delay times can be from 30 to 250 seconds. Repeat the above for Entry Delay
2 if it is being used. Default is 30 seconds for Entry Delay 1.
Note: Specic Exit Error operation is based on the Entry Delay used (1 or 2) with an
EX type zone. See Exit Delay.
CODE CHG NO YES
AMBUSH NO YES
LATE TO OPEN
MINUTES: 0
EARLY TO CLOSE
MINUTES: 0
SYSTEM OPTIONS
SYSTEM: HOME/AWAY
AREA A/P H/A
CLS CODE NO YES
CLS CHK NO YES
ENTRY DLY 1: 30
ENTRY DLY 2: 60
SYSTEM OPTIONS