EasyManuals Logo

DMP Electronics XTLtouch Programming Guide

DMP Electronics XTLtouch
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
17 XTLtouch Series Programming Guide | Digital Monitoring Products
SYSTEM OPTIONS
System Options allows you to select system wide parameters used in the operation of the XTLtouch.
SYSTEM OPTIONS
Press a select area.
SYSTEM
Press a select area to choose the system type. The default is HOME/AWAY (Perimeter,
Interior, and Bedrooms), or you can choose between ALL/PERIMETER (Perimeter/
Interior), or a six-area system. Zones must be assigned to BEDROOMS for the area to
be active. Wireless zones in an Area or All/Perimeter system re-sound the Trouble tone
every four hours when zone trouble or low battery is displayed.
CLOSING CODE
Select YES to require a code number when arming the system. The default is NO.
CLOSING CHECK
Select YES to allow the panel to verify that all areas have been armed after a schedule
expires. If Closing Check finds any areas disarmed past the scheduled time, all keypads
emit a steady beep and display CLOSING TIME!. The user must extend the schedule
or arm the system within ten minutes or a Late to Close message is sent to the central
station. The default is NO.
ENTRY DELAY 1
Enter the entry delay time for all Exit type zones programmed to use Entry Delay 1.
When an armed Exit type zone is faulted, the keypad(s) prewarn tone sounds and
displays ENTER CODE: - and the name of the zone causing the Entry Delay. When the
first user code is entered, the prewarn tone stops at the keypad. If a valid user code is
not entered or an invalid user code is entered, the prewarn tone begins sounding again.
Fifteen seconds must elapse before attempting to silence the prewarn tone with a valid
user code. The system must be disarmed before the entry delay expires or an alarm is
detected. All Burglary type zones in all areas are delayed along with the Exit zone.
The range is 30 to 250 seconds. The default is 30 seconds.
Note: Specific Exit Error operation is based on the Entry Delay used (1 or 2) with an EX
type zone. See Exit Delay.
ENTRY DELAY 2
The range is 30 to 250 seconds. The default is 60 seconds.
EXIT DELAY
Enter the exit delay time for all Exit type zones. When the exit delay time starts, all
activity on exit and burglary zones is ig nored until the time entered expires. The keypad
displays the Exit Delay time countdown and annunciates the Exit Delay tone at 8 second
intervals until the last 10 seconds when annunciation is at 3 second intervals. During Exit
Delay, if an exit zone trips, then restores, and trips again, the Exit Delay timer restarts.
This restart can occur only once. The range is 45 to 250 sec onds. The default is 60
seconds.
SYSTEM OPTIONS
SYSTEM: HOME/AWAY
CLS CODE NO YES
CLS CHK NO YES
ENTRY DLY 1: 30
ENTRY DLY 2: 60
EXIT DELAY: 60

Table of Contents

Other manuals for DMP Electronics XTLtouch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XTLtouch and is the answer not in the manual?

DMP Electronics XTLtouch Specifications

General IconGeneral
BrandDMP Electronics
ModelXTLtouch
CategorySecurity System
LanguageEnglish

Related product manuals