18 XTLtouch Series Programming Guide | Digital Monitoring Products
CROSS ZONE TIME
Enter the time allowed between zone faults. When a zone programmed for cross zoning
faults, the XTLtouch begins counting down the cross-zone time entered here. If the
same zone or another cross-zoned zone faults within this time, an alarm report is sent to
the receiver. If Cross-Zone Time expires without the second zone fault, only a zone fault
report from the first zone is sent to the receiver. The range is 4 to 250 seconds in one
second increments. Enter the default, 0 (ZERO), to disable Cross-Zone Time.
POWER FAIL HOURS
Enter that time that the system should track the duration of an AC power failure. When
the AC power is o for the length of the programmed time, an AC power failure report
is sent to the receiver. Enter 0 (zero) to allow the XTLtouch to send the AC power failure
report to the receiver within 15 seconds. The range is 1 to 9 hours. The default is 1.
SWINGER BYPASS TRIPS
Enter the number of times a zone can go into an alarm or trouble condition within one
hour be fore being auto matically bypassed. Bypassed zones are auto matically reset
when the area they are assigned to is disarmed. All 24-hour zones are reset when any
area of the system is dis armed. The Stop function restores a bypassed zone. The range is
0 to 9. Entering 0 (zero) disables this function. The default is 2.
How it works
The XTLtouch timer starts at 59 minutes past the hour. If the hour timer expires before
the trip counter is exceeded, the trip counter returns to 0 (zero). If the trip counter is
exceeded before the hour expires, the zone is auto matically bypassed by the panel. A
Bypass Re port is sent to the receiver if Bypass Re ports is YES.
Note: Not investigated by Intertek.
RESET SWINGER BYPASS
Select YES to reset an auto matically bypassed zone if it remains in a normal condition
for one hour after being bypassed. A report of the automatic reset is sent to the receiver
if Bypass Reports has been se lected as YES. The default is NO.
Note: Not investigated by Intertek.
ZONE ACTIVITY HOURS
This option provides supervision of a person living alone for non-activity. Enter the
number of hours to elapse without a disarmed zone being tripped before a message
is sent to the receiver. When the system is disarmed, the timer begins to countdown
the number of hours programmed. Each time activity occurs, the timer restarts the
countdown. Before the countdown time expires, the keypad sounds a tone and displays
PRESS ANY KEY to allow the user to manually restart the activity timer. The duration of
the tone is the number of seconds programmed for Entry Delay 2. The range is 1 to 6.
The default is 0 (zero).
Enable the SUPV/TRBL receiver option in Communication programming to allow the
XTLtouch to send an S93 ALARM: User Activity Not Detected, S94 Alert: Activity Check
Enabled, and S95 Alert: Activity Check Disabled messages to the central station.
When an open/close schedule is programmed, the timer only counts down during the
scheduled open period. Also, when a schedule is programmed, if the timer is counting
down and the scheduled open time occurs, the timer resets and begins the countdown
again.
CRS ZONE TM: 0
PWR FAIL HRS: 1
ZN ACTY HRS: 0
SWGRBYPS TRIPS: 2
RST SBYP NO YES

Table of Contents

Other manuals for DMP Electronics XTLtouch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XTLtouch and is the answer not in the manual?

DMP Electronics XTLtouch Specifications

General IconGeneral
BrandDMP Electronics
ModelXTLtouch
CategorySecurity System
LanguageEnglish

Related product manuals