DC-TEC-MAN-CL96_B
DODtec.com
REV 1/9/2024 815-788-5200
Page 16 solutions@dodtec.com
ChemLogic® CL96 Operating Manual
3.6 Output Wiring
See Appendix B for a listing of various output module connections available on the CL96.
3.6.1 Standard Output Wiring
The standard output modules included with the system require an external 24V supply connected to the CL96
to supply power for the outputs.
Use only AWG22 to AWG18 twisted wire (wire sizes UL1015 and UL1007)
Strip from .26” to .31”(6.5mm to 8.0mm) from each wire to insert into the connector.
To connect the wires to the spring-loaded output connector:
• Insert the screwdriver into the square shaped hole which will open the round hole for the wire.
• Continue to hold the screwdriver while inserting the wire into the round shaped hole.
• While holding the wire in place remove the screwdriver which closes the clamp onto the wire.
• IMPORTANT : Be sure the wire is inserted completely into the hole. Failure to do so could result in
system failure, electrical shock.
• To remove a wire, re-insert the screwdriver in the hole as described in step 1 and gently pull the wire out
while the spring is compressed.