ChemLogic® CL96 Operating Manual
Figure G.2.2
G.2.2 Installing the A/C Power Cable
Insert the exposed wires of the power cord through the hole in the fitting from the outside and then into
the cord grip cap as shown in figure G.2.3.
Figure G.2.3
Pull the appropriate length of cord inside the cabinet to allow the shielded portion of the cable to reach
the power filter.
Tighten the cord grip cap shown in Figure G.2.3 back onto the fitting securely to hold the cord in place.
G.2.3 Attaching the A/C Power inside the cabinet
See Figure G.2.4 below for reference
Pull down lightly on the plastic cover on the Power Filter exposing screw connections #1 and #2.
Attach the Neutral/White wire to the Power Filter at the label for Screw #2, tighten securely.