Issued June 2020
Operation
Copyright 2020, Heil Environmental
Printed in U.S.A.
97
UNLOADING AN EJECT UNIT (CONTINUED)
Clean Behind the Packer Panel
1. Extend the packer panel to the rear of the body.
2. Disengage the PTO or Pump Switch
3. Turn OFF engine and REMOVE the ignition key and
place unit in Lock-Out/Tag-Out mode .
DANGER
Before entering the body area, place the unit in Lock-Out/
Tag-Out mode. See Lock-Out/Tag-Out Procedures .
4. Open access door and clean behind the packer
panel after each load.
5. Inspect packer tracks and hopper floor for excessive
wear or possible damage.
6. Close access door and return packer panel to front of
body.
Clean Out Hopper Sump
A sump door is located on the front corner on each side of
the body and needs to be open when cleaning out the
sump area. A cleaning tool is provided with each unit to
clean out the sump area. Clean out the sump area after
unloading at the landfill. Be sure to close and latch BOTH
sump doors when completed.
Sump doors should be closed at all times except when
open for cleaning.
Figure 51. Curb Side Hopper Sump Door Closed
Remove Refuse from the Engine and Exhaust Areas
Inspect unit for refuse on or about the engine or exhaust
components. Remove all refuse to prevent a fire.
Preparing to Return to Route
MAKE SURE before you leave the landfill or transfer station
that the unit is in the In-Transit Position .
32
32
86