EasyManua.ls Logo

Dover Markem-Imaje SmartDate X60 - Master-Slave Function

Dover Markem-Imaje SmartDate X60
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
141 10056272-AA
Master-Slave Function
This allows you to congure one Smartdate (Set as the Master) to control the current
job on another Smartdate (Set as the Slave)
When operating in this mode it is possible to:
Determine the basic operational state of the Slave printer from the Master SmartDate.
Determine if slaves are connected or not and if they are active printing.
Select jobs simultaneously accross two SmartDates (One Master + One Slave) entering
any required data once only.
Jobs can be resident in each SmartDate local database, or these can be downloaded to
Masters and /or Slaves from CoLOS Control.
Optionally, synchronise Start/Stop printing accross slaves.
Synchronise the clock date/time of the slaves to the master. The date and time are
automatically synchronised when the Master connects to the Slave. The time / date
can subsequently be adjusted either through the Master or from a third party host (eg
CoLOS)
Job selection
for parts & service call QLC (800) 837-1309