Printer configuration
161 10056272-AA
  Print Initiation
The Print Initiation menu allows you to configure the signal to start printing. The options 
available will depend upon which printer type is selected. (Intermittent or Continuous)
The following Print Initiation options can be configured:
Setting Description
Print Trigger
Range: External, Internal or 
Combined.
Default: External
This is Continuous printer feature.
This allows you to set the print trigger source.
Debounce Time
Range: 0 to 5000 ms
Default: 10
This is an Intermittent printer feature.
This allows you to set the time over which the print trigger must be active 
before it is accepted as valid. This avoids electrical noise problems.
Debounce Distance
Range: 0 to 5 mm
Default: 0
This is Continuous printer feature.
This allows you to set the distance over which the print trigger must be active 
before it is accepted as valid. This avoids electrical noise problems.
Pack Length
Range: 0 mm to 1200 mm 
Default: 2 mm
This is Continuous printer feature.
This allows you to set the distance following a valid print go signal that the 
printer will ignore subsequent print signals.
Fixed Spacing Distance
Range: 10 - 2000 mm
Default: 150 mm
This is Continuous printer feature.
When the print trigger is set to Internal or Combined this allows you to define 
the distance between the leading edges of the prints on the substrate.
Fixed Spacing Count
Range: 1 - 65535
Default: 1
This is Continuous printer feature.
When the print trigger is set to Combined this allows you to define the number 
of prints following a Print Go signal.
Unexpected Print Fault Threshold
Range: 0 to 100
Default: 10
This allows you to set the number of acceptable missed prints before a fault is 
raised.
Print Signal Expected Threshold 
Range: 0 to 1000
Default: 0
This is a Continuous printer feature.
This allows you to set the distance that the substrate is allowed to travel 
without an expected print go signal and before a fault is raised.
Print Go Signal
Range: Active Low or Active High
Default: Active Low
This allows to to set the print trigger to be activated when high or low.
for parts & service call QLC (800) 837-1309