EasyManua.ls Logo

Dover Markem-Imaje SmartDate X60 - Print Features Configuration

Dover Markem-Imaje SmartDate X60
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Printer conguration
161 10056272-AA
Print Initiation
The Print Initiation menu allows you to congure the signal to start printing. The options
available will depend upon which printer type is selected. (Intermittent or Continuous)
The following Print Initiation options can be congured:
Setting Description
Print Trigger
Range: External, Internal or
Combined.
Default: External
This is Continuous printer feature.
This allows you to set the print trigger source.
Debounce Time
Range: 0 to 5000 ms
Default: 10
This is an Intermittent printer feature.
This allows you to set the time over which the print trigger must be active
before it is accepted as valid. This avoids electrical noise problems.
Debounce Distance
Range: 0 to 5 mm
Default: 0
This is Continuous printer feature.
This allows you to set the distance over which the print trigger must be active
before it is accepted as valid. This avoids electrical noise problems.
Pack Length
Range: 0 mm to 1200 mm
Default: 2 mm
This is Continuous printer feature.
This allows you to set the distance following a valid print go signal that the
printer will ignore subsequent print signals.
Fixed Spacing Distance
Range: 10 - 2000 mm
Default: 150 mm
This is Continuous printer feature.
When the print trigger is set to Internal or Combined this allows you to dene
the distance between the leading edges of the prints on the substrate.
Fixed Spacing Count
Range: 1 - 65535
Default: 1
This is Continuous printer feature.
When the print trigger is set to Combined this allows you to dene the number
of prints following a Print Go signal.
Unexpected Print Fault Threshold
Range: 0 to 100
Default: 10
This allows you to set the number of acceptable missed prints before a fault is
raised.
Print Signal Expected Threshold
Range: 0 to 1000
Default: 0
This is a Continuous printer feature.
This allows you to set the distance that the substrate is allowed to travel
without an expected print go signal and before a fault is raised.
Print Go Signal
Range: Active Low or Active High
Default: Active Low
This allows to to set the print trigger to be activated when high or low.
for parts & service call QLC (800) 837-1309

Table of Contents

Other manuals for Dover Markem-Imaje SmartDate X60

Related product manuals