Printer configuration
159 10056272-AA
Date Rollover Direction
Range: After Midnight or Before 
Midnight
Default: After Midnight
This allows you to set the period of the day that the rollover occurs.
Offset Date Rollover Hour
Range: 0 to 11
Default: 0
(Best Before End)
This allows you to set the hour at which the next day starts.
Offset Date Rollover Minute
Range: 0 to 59
Default: 0
(Best Before End)
This allows you to set the minute of the hour at which the next day starts.
Offset Date Rollover Direction
Range: After Midnight or Before 
Midnight
Default: After Midnight
(Best Before End)
This allows you to set the period of the day that the rollover occurs.
Image Refresh
Range: Every Second or every 
Minute
Default: Every Minute
This allows you to set the update period for viewing the selected job on the 
Home screen when in producing mode.
Data Queue Size
Range: 0 to 200
Default: 0
This is used with per-print variable data queueing. This allows the SmartDate 
to buffer field data for a number of packs ahead of the one being printed. 
Normally used in conjuction with weigh scale equipment and allows the weigh 
scale equipment to communicate information for the pack it has just weighed 
Data Queue Low Water Mark
Range: 0 to 200
Default: 0
This allows you to set the limit at which an update request is sent to the host 
machine 
for parts & service call QLC (800) 837-1309