Settings via the software
Operating Instructions 878-M PREMIUM - 02.0 - 02/2018 75
Top roller pressure
Value range: 1 to 14
•Use
/ to select the Top roller pressure parame-
ter.
•Use
/ to change the top roller pressure
Difference feed between top roller and wheel feeder
Value range: 0 to 16 (increments 1)
•Use
/ to select the Difference feed parameter.
•Use +/- to select difference sense
•Use
/ or the numeric keys to change the differ-
ence value
Other parameters
8.4.2 Menu for other settings, str. 77
S.p.m. or seam length in mm
After the thread has been cut off, the display is
retained. Measurement/counting restarts when sewing
starts again.
P Creating a program
8.6.1 Creating programs, str. 82
+/- Altering sense of difference feed (wavy line up - top
roller feeds faster; wavy line down - top roller feeds
slower)
ESC, F and S No function assigned
OK No function assigned
Symbol Meaning