Settings via the software
Operating Instructions 878-M PREMIUM - 02.0 - 02/201880
8.5.1 Before starting sewing
1. Sew, press the pedal or press the OK key.
The program switches to the 1st section.
Symbol Meaning
Programming (depending on assignment)
• Press the upper softkey
Quick access function (softkey menu)
• Press the lower softkey
8.4.1 Quick access func-
tion (softkey menu), str. 76.
Program number
Value range: 000 to 999
•Use
/ to select the Program parameter.
•Use
/ to change the program number.
Or:
• Input the program number using the 0 - 9 keys
and confirm with OK as required.
If you select program 000, the controller selects
Manual mode
Seam sections
Number of sections contained in the current program.
Stitch length correction factor
Value range: -50 to +50 %
Alters the stitch length in all seam sections.
Thread tension correction factor (only for electronic
tension plate)
Value range: -50 to +50 %
Alters the thread tension in all seam sections.