www.eaton.com IM02601001E C-15
Modbus Register Maps
Parameter Name Display Name Base Address
(0-based)
Discrete Units Type Size
(bytes)
Is Time-
stamp
Bit
Offset
Swap
Bytes
Swap
Words
Divider Multiplier Date
Spec
Alarm On
False
Writable Possible Values
mSourceRegOutput4/Value Source Measure for Output 4 27624 No no-units UINT 2 No No No Yes Not Assigned(0); Van(999);
Vbn(1001); Vcn(1003); Vab(1005);
Vbc(1007); Vca(1009); Ia(1011);
Ib(1013); Ic(1015); Total
Watts(1017); Total VARs(1019);
Total VA(1021); Total PF(1023);
Frequency(1025); In(1027); Watts
Phase A(1029); Watts Phase
B(1031); Watts Phase C(1033);
VARs Phase A(1035); VARs Phase
B(1037); VARs Phase C(1039); VA
Phase A(1041); VA Phase B(1043);
VA Phase C(1045); PF Phase
A(1047); PF Phase B(1049); PF Phase
C(1051); Demand Ia(1999); Demand
Ib(2001); Demand Ic(2003); Demand
Forward Watts(2005); Demand Lag-
ging VARs(2007); Demand Reverse
Watts(2009); Demand Leading
VARs(2011); Demand VAs(2013);
Avg Demand Lagging PF(2015); Avg
Demand Leading PF(2017); Demand
In(2019); Avg Demand Lagging PF
Phase A(2051); Avg Demand Lag-
ging PF Phase B(2053); Avg Demand
Lagging PF Phase C(2055); Avg
Demand Leading PF Phase A(2057);
Avg Demand Leading PF Phase
B(2059); Avg Demand Leading PF
Phase C(2061); THD Van(5999); THD
Vbn(6000); THD Vcn(6001); THD
Ia(6002); THD Ib(6003); THD Ic(6004)
mHighValueOutput4/Value Output 4 Source Register High Value 27625 No no-units FLOAT 4 No No No Yes
mLowValueOutput4/Value Output 4 Source Register Low Value 27627 No no-units FLOAT 4 No No No Yes

Parameter Name Display Name Base Address
(0-based)
Discrete Units Type Size
(bytes)
Is Time-
stamp
Bit
Offset
Swap
Bytes
Swap
Words
Divider Multiplier Date
Spec
Alarm On
False
Writable Possible Values
VendorName/Value Vendor Name 1032 No no-units STRING 64 No No No No
ModelName/Value Model Name 1064 No no-units STRING 64 No No No No
iDisplayName/Value Display Name 1096 No no-units STRING 64 No No No Yes
SerialNumber/Value Serial Number 1276 No no-units STRING 64 No No No No
SoftwareVersion/Value Software Version 2108 No no-units STRING 48 No No No No
iFieldReplaceableUnit/Value Field Replaceable Unit 1605 No no-units UINT 2 No No No Yes true;false
mDI1Accum/Value Input 1 Accumulator - Scaled 10000 No no-units UINT 4 No No No No
mDI2Accum/Value Input 2 Accumulator - Scaled 10002 No no-units UINT 4 No No No No