Appendix A—Parameter ID list
POWERXL DG1 SERIES VFD MN040010EN—September 2016 www.eaton.com
Table 188. Parameter ID list, continued
Menu
Item No.
Modbus
Register
Profibus
PNU
Profibus
PNU
SubIndex
EtherNet/
IP Class
EtherNet/
IP Instance
EtherNet/
IP Attribute
DeviceNET
Class
DeviceNET
Instance
DeviceNET
Attribute Parameter Description
P2.3.3 184 264 1 160 1 59 163 1 13 AI2 Custom Min
P2.3.4 185 265 1 160 1 60 163 1 14 AI2 Custom Max
P2.3.5 182 266 1 160 1 61 163 1 15 AI2 Filter Time
P2.3.6 189 267 1 160 1 67 163 1 16 AI2 Signal Invert
P2.3.7 186 1711 1 160 1 68 163 1 17 AI2 Joystick Hyst
P2.3.8 187 1720 1 160 1 69 163 1 18 AI2 Sleep Limit
P2.3.9 188 1721 1 160 1 70 163 1 19 AI2 Sleep Delay
P2.3.10 134 1712 1 160 1 71 163 1 20 AI2 Joystick Offset
P2.4.1 2484 NA NA NA NA NA NA NA NA Fine Tuning Input
P2.4.2 2485 NA NA NA NA NA NA NA NA Fine Tuning Min
P2.4.3 2486 NA NA NA NA NA NA NA NA Fine Tuning Max
P3.1 143 425 0 160 1 169 164 1 1 IO Terminal 1 Start Stop Logic
P3.2 190 414 0 160 1 72 164 1 2 IO Terminal 1 Start Signal 1
P3.3 191 414 1 160 1 73 164 1 3 IO Terminal 1 Start Signal 2
P3.4 881 409 0 160 1 200 164 1 4 Thermistor Input Select
P3.5 198 421 2 160 1 74 164 1 5 Reverse
P3.6 192 446 0 160 1 75 164 1 6 Ext. Fault 1 NO
P3.7 193 447 0 160 1 76 164 1 7 Ext. Fault 1 NC
P3.8 200 400 7 160 1 77 164 1 8 Fault Reset
P3.9 194 400 16 160 1 78 164 1 9 Run Enable
P3.10 205 432 0 160 1 79 164 1 10 Preset Speed B0
P3.11 206 432 1 160 1 80 164 1 11 Preset Speed B1
P3.12 207 432 2 160 1 81 164 1 12 Preset Speed B2
P3.13 550 2134 0 160 1 82 164 1 13 PID1 Control Enable
P3.14 553 2134 1 160 1 83 164 1 14 PID2 Control Enable
P3.15 195 435 0 160 1 84 164 1 15 Accel/Decel Time Set
P3.16 201 400 5 160 1 85 164 1 16 Accel/Decel Prohibit
P3.17 215 402 5 160 1 86 164 1 17 No Access To Param
P3.18 203 421 4 160 1 87 164 1 18 Accel Pot Value
P3.19 204 421 5 160 1 88 164 1 19 Decel Pot Value
P3.20 216 405 0 160 1 89 164 1 20 Reset Pot Zero
P3.21 196 406 0 160 1 90 164 1 21 Remote Control
P3.22 197 406 1 160 1 91 164 1 22 Local Control
P3.23 209 407 0 160 1 92 164 1 23 Remote 1/2 Select
P3.24 217 417 0 160 1 93 164 1 24 Second Motor Para Select
P3.25 218 NA NA 160 1 94 164 1 25 Bypass Start
P3.26 202 402 4 160 1 95 164 1 26 DC Brake Active
P3.27 219 402 2 160 1 96 164 1 27 Smoke Mode
P3.28 220 402 3 160 1 97 164 1 28 Fire Mode
P3.29 221 439 0 160 1 98 164 1 29 Fire Mode Ref 1/2 Select
P3.30 351 410 0 160 1 99 164 1 30 PID1 Set Point Select
P3.31 352 410 1 160 1 100 164 1 31 PID2 Set Point Select
P3.32 199 400 8 160 1 101 164 1 32 Jog Enable
P3.33 224 3104 0 160 1 102 164 1 33 Start Timer 1
P3.34 225 3104 1 160 1 103 164 1 34 Start Timer 2
P3.35 226 3104 2 160 1 104 164 1 35 Start Timer 3
P3.36 208 415 0 160 1 105 164 1 36 AI Ref Source Select
P3.37 210 1910 0 160 1 106 164 1 37 Motor Interlock 1
P3.38 211 1910 1 160 1 107 164 1 38 Motor Interlock 2