Electronic Clutch Actuator (ECA) Removal and Installation | Service Procedures TRSM0940
2. Install the 4 cap screws from the ECA mounting flange.
Tighten them to 35–45 lb-ft (47–61 N•m).
Note: The
cap screws for the ECA are longer than the
ECA Bracket cap screws.
Note: En
sure the ECA does not bind on the Cross-Shaft
by snugging all cap screws before tightening to the
specified torque.
3. If applica
ble, install the 4 cap screws for the ECA
Shield. Tighten them to 35–45 lb-ft (47–61 N•m).
4. Apply
NyoGel to terminals and reconnect the 8-way
and 3-way connectors to the ECA.
Note: Ap
ply just enough material to cover the end of
the terminal.
Note: Use on
ly Eaton lubricant part number 5564527
(Nye Lubricants NYOGEL 760G. For MSDS safety or
other information see www.nyelubricants.com.)
5. Reconnec
t the negative 12-volt battery cable.
6. If
previously removed, install the 8-bolt PTO after ECA
installation. Follow the PTO manufacturer’s guidelines
for installation instructions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton UltraShift PLUS Series and is the answer not in the manual?

Eaton UltraShift PLUS Series Specifications

General IconGeneral
BrandEaton
ModelUltraShift PLUS Series
CategoryMicrophone system
LanguageEnglish

Related product manuals