TRSM0940 Service Procedures | Rail Position Sensor Removal and Installation
Rail Position Sensor Installation
1. Align sensor tabs with the slot in the X-Y Shifter Rail.
Then, insert the Rail Position Sensor, with gasket, into
its mounting location.
Note: Install the sensor,
so connector opening faces
right side of the Transmission. (As viewed from the
rear of the transmission)
2. Using a 5/32”
hex key wrench, install the 2 hex key
mounting screws and tighten to 21–27 lb-in (2.3–3.0
N•m).
Caution: Carefully hold sensor in position while install-
ing the hex key mounting screws, or
sensor can snap.
3. Reconnec
t the Transmission Harness to the Rail Posi-
tion Sensor.
!