2018.12.12
© 2017 Eaton. All rights reserved
212
TRSM0940 Service Procedures | X-Y Shifter Removal and Installation 
4. Position X-Y Shifter on the Shift Bar Housing. Using a 
9/16” socket, install mounting cap screws and tighten 
in a cross pattern as follows:
• Tigh
ten to 30–35 lb-ft (45–60 N•m). 
5. Reconnect the Rail 
Position Sensor and Gear Position 
Sensor.
6. Reconnec
t the Transmission Harness to the Rail Select 
and Gear Select Motors. Using cable ties, secure motor 
wires to the Transmission in their previous position. 
7. To 
operate properly, the system must be calibrated as 
follows:
Important: X-Y Shifter must be calibrated before the 
vehicle is placed into operation. 
• Turn ignition switch 
on. Allow the Transmission to 
power up.
• Tu
rn ignition switch off. Wait 2 minutes.