TRSM0940 Service Procedures | X-Y Shifter Removal and Installation
4. Position X-Y Shifter on the Shift Bar Housing. Using a
9/16” socket, install mounting cap screws and tighten
in a cross pattern as follows:
Tigh
ten to 30–35 lb-ft (45–60 N•m).
5. Reconnect the Rail
Position Sensor and Gear Position
Sensor.
6. Reconnec
t the Transmission Harness to the Rail Select
and Gear Select Motors. Using cable ties, secure motor
wires to the Transmission in their previous position.
7. To
operate properly, the system must be calibrated as
follows:
Important: X-Y Shifter must be calibrated before the
vehicle is placed into operation.
Turn ignition switch
on. Allow the Transmission to
power up.
Tu
rn ignition switch off. Wait 2 minutes.
!