TRSM0940 Service Procedures | LAS/VAS Auxiliary Section Removal and Disassembly
2. Place the Low Range Synchronizer on a bench with the
larger ring facing down, (place a shop towel over the
assembly to avoid losing any springs) pull the High
Range Synchronizer from the Blocker Ring
3. Remove
the Sliding Clutch from the pins of the Syn-
chronizer Ring.