73
© 2017 Eaton. All rights reserved
2018.12.12
VCS/VMS Combination Cylinder Disassembly and Assembly | Service Procedures TRSM0940
3. Install a new gasket on the Range Cylinder Housing
Mounting Surface and Install the Cylinder housing into
the Auxiliary Case Housing.
4. Lean the Auxiliary section back w
ith the Range Cylinder
upward. Insert the Range piston with flat side to rear.
Push it as far back as far as it will go.
5. Secu
re the Range piston with the 15/16” retaining nut,
torque to 70-85 lb-ft (94.91-115.24 N•m).
6. In
sert the Reduction piston with flat side to rear. Push
it as far back as far as it will go.
7. Secure the Range pist
on with the 3/4” retaining nut,
torque to 50-65 lb-ft.
Note: If reusing existing nut, make
sure the nylon lock-
ing material is in good shape. Replace if not.