17 PLC shell commands
17.2 List of PLC shell commands (updated)
Modular PLCs XControl: XC-104-…, XC-204-…, XC-303-… 01/23 MN050005EN Eaton.com 161
stopprg Stop user program
storagestate
2)
Shows the storage state.
Example:
USB Storage Devices mounted: 0
SD Storage Devices mounted: 0
usbautostartdisable
2)
Disables the USB interface; USB Autostart=disabled
usbautostartenable
2)
If a USB data storage device is plugged into the USB port, projects will be started there automatically;
USB Autostart=enabled
usbdisable
2)
Disables the USB interface.
usbenable
2)
Enables the USB interface; a USB data storage device can be read.
usbstate
2)
Shows the USB state
Example:
USB Storage=enabled
USB Autostart=enabled
unmountall
2)
Terminates the connection to all active USB partitions.
xngetversion Shows version information; shows current XN driver version
xnmodules shows currently configured and connected SDIAS modules
xnvariables shows XN module variables
xnconfig shows XN module configuration variables
xndebug
2)
Example:
Debug level is set to 3
1) You can access help with extended information for this PLC shell command in CODESYS. Enter a question mark followed by a space before the command
e.g.: ? plcload in the command line of the PLC browser
2) Available for devices with runtime system version 3.5.17 or higher
Attribute ID