Chapter 17
| UniDirectional Link Detection Commands
– 483 –
udld recovery This command configures the switch to automatically recover from UDLD disabled
port state after a period specified by the udld recovery-interval command. Use the
no form to disable this feature.
Syntax
[no] udld recovery
Default Setting
Disabled
Command Mode
Global Configuration
Command Usage
When automatic recovery state is changed by this command, any ports shut down
by UDLD will be reset.
Example
Console(config)#udld recovery
Console(config)#
udld recovery-interval This command specifies the period after which to automatically recover from UDLD
disabled port state. Use the no form to restore the default setting.
udld recovery-interval recovery-interval
no recovery-interval
recovery-interval – The interval after which a port is reset after being placed
in UDLD disabled state. (Range: 30-86400 seconds)
Default Setting
300 seconds
Command Mode
Global Configuration
Command Usage
â—† This command is only applicable when automatic recovery has been enabled
with the udld recovery command.
â—† When the recovery interval is changed by this command, any ports shut down
by UDLD will be reset.

Table of Contents

Other manuals for Edge-Core ECS4120-52T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS4120-52T and is the answer not in the manual?

Edge-Core ECS4120-52T Specifications

General IconGeneral
BrandEdge-Core
ModelECS4120-52T
CategorySwitch
LanguageEnglish

Related product manuals