Chapter 26
| CFM Commands
Defining CFM Structures
– 787 –
This example shows the configuration status for continuity check and cross-check
traps.
Console#show ethernet cfm configuration traps
CC MEP Up Trap :Disabled
CC MEP Down Trap :Disabled
CC Configure Trap :Disabled
CC Loop Trap :Disabled
Cross Check MEP Unknown Trap :Disabled
Cross Check MEP Missing Trap :Disabled
Cross Check MA Up :Disabled
Console#
This example shows the CFM status for port 1.
Console#show ethernet cfm configuration interface ethernet 1/1
Ethernet 1/1 CFM Status:Enabled
Console#
Table 158: show ethernet cfm configuration traps - display description
Field Description
CC MEP Up Trap Sends a trap if a remote MEP is discovered and added to the local
database, the port state of a previously discovered remote MEP changes,
or a CCM is received from a remote MEP which as an expired entry in the
archived database.
CC Mep Down Trap Sends a trap if this device loses connectivity with a remote MEP, or
connectivity has been restored to a remote MEP which has recovered from
an error condition.
CC Configure Trap Sends a trap if this device receives a CCM with the same MPID as its own
but with a different source MAC address, indicating that a CFM
configuration error exists.
CC Loop Trap Sends a trap if this device receives a CCM with the same source MAC
address and MPID as its own, indicating that a forwarding loop exists.
Cross Check MEP
Unknown Trap
A CCM is received from a MEP that has not been configured as a DSAP (see
the ethernet cfm mep command), manually configured as a remote MEP
(see the mep crosscheck mpid command), nor learned through previous
CCM messages.
Cross Check MEP Missing
Trap
This device failed to receive three consecutive CCMs from another MEP in
the same MA.
Cross Check MA Up Generates a trap when all remote MEPs belonging to an MA come up.

Table of Contents

Other manuals for Edge-Core ECS4120-52T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS4120-52T and is the answer not in the manual?

Edge-Core ECS4120-52T Specifications

General IconGeneral
BrandEdge-Core
ModelECS4120-52T
CategorySwitch
LanguageEnglish

Related product manuals