EasyManua.ls Logo

Edwards SCU-800

Edwards SCU-800
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SCU-800 Control Unit for Turbomolecular Pump
MT-49E-101-G
Page 114
7
MAINTENANCE
Referred
section
3.4.1
3.4.3
3.4.1
3.4.3
*1
The driver output stops and the rotor continue rotating by inertia. It may take several hours to stop. To stop the STP pump quickly, close the vacuum valve at the outlet port
flange and introduce gas from the purge port into the STP pump.
Table
34
-
Error
m
essages after self test
Countermeasures
Check the vacuum piping
system for leakage. Check the
exhaust sequence.
Contact
Service office.
1.
Perform rotational
operation after resetting.
2.
Contact Service office.
C
ontact Service office.
1.
Set the ambient
temperature to 40 ºC (104
ºF) or less.
2.
Remove obstacle from the
ventilation port.
1.
Set the ambient
temperature to 40 ºC (104
ºF) or less.
2.
Remove obstacle from the
ventilation port.
Probable causes
Atmospheric air flows the STP
pump
.
Failure of the
SCU-800.
1.
Malfunction by external
noise.
2.
Failure of the SCU-800.
Short
-circuit or ground fault in
the connection cable or at
connector part
.
1.
High ambient temperature.
2.
Insufficient cooling of the
SCU-800.
1.
High ambient temperature.
2.
Insufficient cooling of the
SCU-800.
Pump operation
Decelerate and stop,
then Touch down
.
The magnetic
bearing output stops
and the rotor is
descended on the
protection bearing.
Free run.
*1
Stop
Touch down
. The
magnetic bearing
output stops and the
rotor is descended
on the prot
ection
bearing.
Continuance of
rotation.
Decelerate and stop.
Occurrence condition
R
otational speed rises
when deteriorating or
stopping.
When the rated operation
does not stop approx. 30
min. after start operation is
executed.
Accelerate up to 500
rpm
or less
.
Excessive magnetic
bearing electric current
.
Overheat inside the
SCU
-800.
Overheat inside the
SCU
-800.
LCD Messages
Aberrant Accel
Aberrant Brake
Accel Malfunction
Amp Overcurrent
CAUTION:
CNT heat1
CNT Overheat 1

Table of Contents

Related product manuals