Manually Zone Switches and Configure System LUNs
EMC CONFIDENTIAL
3. For the 64-gigabyte LUN, enter this command:
#
navicli -h <SP_A_IP_address> storagegroup -addhlu -gname
<storage_group_name> -hlu 5 -alu 5
4. To verify that the LUNs were correctly assigned, use the following commands:
#
navicli -h <SP_A_IP_address> getlun -capacity
# navicli -h <SP_A_IP_address> getall -sg
Note: The getlun -capacity argument lists the LUNs by ALU and size. The getall -sg
argument lists the ALU to HLU mapping.
Verify the following information:
• The two 11-gigabyte (reported as 11264 megabytes) control LUNs map to HLU
0 and 1.
• The three 2-gigabyte (2048 megabyte) control LUNs map to HLU 2, 3, and 4.
• The 64-gigabyte (65536 megabyte) control LUN maps to HLU 5.