274 E300 Design Guide
Issue Number: 1
See T24 Digital I/O 01 Invert (F12).
See T24 Digital I/O 01 Source/Destination (F18).
See T24 Digital I/O 01 Source/Destination (F18).
See T24 Digital I/O 01 State (F03).
See T24 Digital I/O 01 Invert (F12).
F28 T41 T42 Relay Output Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0Off
1On
F29 T22 24V Supply Output Source
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
F30 T2 24V Supply Input Destination
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, DE, PT, BU
F31 T22 24V Supply Output State
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 1 Units
Type 1 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, BU
F32 T22 24V Supply Output Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 1 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0Off
1On