Issue Number: 1
Mode: Open-Loop, RFC-A, RFC-S
This is V1 speed reference and is set in mm / s.
Nominal Elevator Speed (E01) defines the maximum limit for this parameter.
This is V2 speed reference and is set in mm / s.
Nominal Elevator Speed (E01) defines the maximum limit for this parameter.
This is V3 speed reference and is set in mm / s.
Nominal Elevator Speed (E01) defines the maximum limit for this parameter.
G44 Peak Curve Activated Off (0) or On (1) Off (0) RO Bit
G45 Start Optimizer Enable
Off (0) or On (1) Off (0) RW Bit US
G46 Start Optimizer Speed 0 to 10000 mm/s 50 mm/s 10 mm/s RW Num US
G47 Start Optimizer Jerk
±VM_EX00_RUN_JERK_1 mm/s x10 1 mm/s³ x10 RW Num US
G48 Start Optimizer Time
0 to 10000 ms 500 ms RW Num US
G49 Analog Speed Reference -32768 to 32767 0
RW Num
G50
Analog Speed Reference
Filter Time Constant
0 to 500 ms 16 ms RW Num US
G51 Control Word 0000000000000000 to 1111111111111111 0000000000000000 RW Bin
G52 Creep Speed Select
V1 Is Creep Spd (1)
V2 Is Creep Spd (2)
V3 Is Creep Spd (3)
V4 Is Creep Spd (4)
V5 Is Creep Spd (5)
V6 Is Creep Spd (6)
V7 Is Creep Spd (7)
V8 Is Creep Spd (8)
V9 Is Creep Spd (9)
V10 Is Creep Spd (10)
V1 Is Creep Spd (1) RW Txt PT US
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save
G01 V1 Speed Reference
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
VM_EX00_NOMINAL_ELEVATOR_SPEED
Default 50 Units mm / s
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, VM
G02 V2 Speed Reference
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
VM_EX00_NOMINAL_ELEVATOR_SPEED
Default 400 Units mm / s
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, VM
G03 V3 Speed Reference
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
VM_EX00_NOMINAL_ELEVATOR_SPEED
Default 600 Units mm / s
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, VM