This input bit is used to select the bit 1 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V2 Speed Reference (G02), but in binary input mode it may be used to select a number of speeds from V2 to V10.
This input bit is used to select the bit 2 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V3 Speed Reference (G03), but in binary input mode it may be used to select a number of speeds from V4 to V10.
This input bit is used to select the bit 3 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V4 Speed Reference (G04), but in binary input mode it may be used to select a number of speeds from V8 to V10.
This input bit is used to select the bit 4 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V5 Speed Reference (G05), but in binary input mode it is not used.
This input bit is used to select the bit 5 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V6 Speed Reference (G06), but in binary input mode it is not used.
G33 Reference Select Bit 1 Input
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms
Display Format Standard Decimal Places 0
Coding RW
G34 Reference Select Bit 2 Input
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms
Display Format Standard Decimal Places 0
Coding RW
G35 Reference Select Bit 3 Input
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms
Display Format Standard Decimal Places 0
Coding RW
G36 Reference Select Bit 4 Input
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms
Display Format Standard Decimal Places 0
Coding RW
G37 Reference Select Bit 5 Input
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms
Display Format Standard Decimal Places 0
Coding RW