This is the fast stop deceleration rate, and is set in mm / s
2
. This is activated when Fast Stop Enable (H26) or Rapid Slow Down Enable (H27) = On
(1), and is activated via a digital input or comms from the elevator controller.
This sets the short floor landing distance in mm. This is the distance from the current floor to next the floor level. It is intended for situations where the
distance to the next floor is shorter than normal e.g.0.7 m.
When this feature is used the entire profile will be completed as a position controlled profile. For this reason Start optimization is not available when
using this mode.
This parameter is used when Short Floor Landing Enable (H22) = On (1).
This sets the floor sensor correction target distance in mm. This is the distance from the sensor / limit switch to the floor level. It is assumed that the
distance is symmetrical above and below the floor level.
This parameter is used when Floor Sensor Correction Enable (H23) = On (1).
The remaining distance to floor is shown in Remaining Floor Sensor Correction Distance (J47).
This input bit is used to select the bit zero speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary
1 Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V1 Speed Reference (G01), but in binary input mode it may be used to select a number of speeds from V1 to V10.
G29 Fast Stop Deceleration Rate
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
10000
Default 500 Units mm / s²
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW
G30 Short Floor Landing Distance
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G31 Floor Sensor Correction Target Distance
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G32 Reference Select Bit 0 Input
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum
1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms
Display Format Standard Decimal Places 0
Coding RW