This sets the Direct to floor deceleration distance setpoint in mm for V6 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V7 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V8 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V9 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V10 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G24 V6 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G25 V7 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G26 V8 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G27 V9 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G28 V10 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US