This sets the Direct to floor deceleration distance setpoint in mm for V1 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V2 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V3 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V4 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V5 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G19 V1 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G20 V2 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G21 V3 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G22 V4 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US
G23 V5 Deceleration Distance Setpoint
Mode RFC-A, RFC-S
Minimum 0 Maximum 10000
Default 0 Units mm
Type 16 Bit User Save Update Rate Background
Display Format Standard Decimal Places 0
Coding RW, Num, US