E300 Design Guide 303
Issue Number: 1
This parameter allows the user to select which of the speeds, V1 Speed Reference (G01) to V10 Speed Reference (G10) is used as the Creep Speed
in creep to floor mode Elevator Control Mode (H19) = Creep To Floor (0). From default V1 is the Creep Speed.
When modifying this parameter from V1 Is The Creep Speed (1) in a priority based control input mode (Control Input mode (H11) = Priority 1 Dir (2),
Priority 2 Dir (4) or Control Word (6), it is important to note that the creep speed must be the lowest numbered speed that is to be selected. Failure to
do this will result in the creep speed being selected with priority over a higher travel speed e.g. if V5 is the creep speed and V3 is the nominal speed
when V5 and V3 are selected together V5 has priority so the system will run at the creep speed instead of V3 nominal speed, however, if V3 is the
creep speed and V5 is the nominal speed and V3 and V5 are selected together the system will run at the nominal speed.