Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide 343
Issue Number: 1
When V5 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V5 (5) this shows the distance from V5 Speed Reference (G05) to a stop in mm. The distance is calculated from
V5 Speed Reference (G05), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V5 is not the creep speed in creep to floor mode:
This indicates the distance from V5 Speed Reference (G05) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V5 Speed Reference (G05), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V5 Speed Reference (G05) to a stop in mm. The
distance is calculated from V5 Speed Reference (G05), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
When V6 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V6 (6) this shows the distance from V6 Speed Reference (G06) to a stop in mm. The distance is calculated from
V6 Speed Reference (G06), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V6 is not the creep speed in creep to floor mode:
This indicates the distance from V6 Speed Reference (G06) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V6 Speed Reference (G06)
, the creep speed defined by Creep Speed
Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V6 Speed Reference (G06) to a stop in mm. The
distance is calculated from V6 Speed Reference (G06), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
When V7 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V7 (7) this shows the distance from V7 Speed Reference (G07) to a stop in mm. The distance is calculated from
V7 Speed Reference (G07), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V7 is not the creep speed in creep to floor mode:
This indicates the distance from V7 Speed Reference (G07) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V7 Speed Reference (G07), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V7 Speed Reference (G07) to a stop in mm. The
distance is calculated from V Speed Reference (G07), Deceleration Rate (G12), Run Jerk 3 (G15) a
nd Run Jerk 4 (G16).
J14 V5 Calculated Deceleration Distance
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J15 V6 Calculated Deceleration Distance
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J16 V7 Calculated Deceleration Distance
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT