EasyManua.ls Logo

Emerson E300 Series - Page 342

Emerson E300 Series
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
342 E300 Design Guide
Issue Number: 1
When V2 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V2 (2) this shows the distance from V2 Speed Reference (G02) to a stop in mm. The distance is calculated from
V2 Speed Reference (G02), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V2 is not the creep speed in creep to floor mode:
This indicates the distance from V2 Speed Reference (G02) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V2 Speed Reference (G02), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V2 Speed Reference (G02) to a stop in mm. The
distance is calculated from V2 Speed Reference (G02), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
When V3 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V3 (3) this shows the distance from V3 Speed Reference (G03) to a stop in mm. The distance is calculated from
V3 Speed Reference (G03), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V3 is not the creep speed in creep to floor mode:
This indicates the distance from V3 Speed Reference (G03) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V
3
Speed Reference (G03), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V3 Speed Reference (G03) to a stop in mm. The
distance is calculated from V3 Speed Reference (G03), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
When V4 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V4 (4) this shows the distance from V4 Speed Reference (G04) to a stop in mm. The distance is calculated from
V4 Speed Reference (G04), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V4 is not the creep speed in creep to floor mode:
This indicates the distance from V4 Speed Reference (G04) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V4 Speed Reference (G04), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V4 Speed Reference (G04) to a stop in mm. The
distance is calculated from V4 Speed Reference (G04), Deceleration Rate
(
G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
J11 V2 Calculated Deceleration Distance
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J12 V3 Calculated Deceleration Distance
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
J13 V4 Calculated Deceleration Distance
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10000
Default Units
Type 16 Bit Volatile Update Rate Background
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT