374 E300 Design Guide
Issue Number: 1
Logic Function 2 Output (K09) shows the output of logic function 2.
Logic Function 2 Source 1 (K10) defines input source 1 of logic function 2.
Setting Logic Function 2 Source 1 Invert (K11) inverts input 1 of logic function 2.
Logic Function 2 Source 2 (K12) defines input source 2 of logic function 2.
Setting Logic Function 2 Source 2 Invert (K13) inverts input 2 of logic function 2.
Setting Logic Function 2 Output Invert (K14) inverts the output of logic function 2.
K09 Logic Function 2 Output
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default Units
Type 1 Bit Volatile Update Rate 4 ms write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
K10 Logic Function 2 Source 1
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
K11 Logic Function 2 Source 1 Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 0
Coding RW
K12 Logic Function 2 Source 2
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
K13 Logic Function 2 Source 2 Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 0
Coding RW
K14 Logic Function 2 Output Invert
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 0 Units
Type 1 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 0
Coding RW