E300 Design Guide 383
Issue Number: 1
See Variable Selector 1 Source 1 (K30).
See Variable Selector 1 Source 1 (K30).
See Variable Selector 1 Source 1 (K30).
See Variable Selector 1 Source 1 (K30).
K46 Variable Selector 2 Source 2
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, PT, BU
K47 Variable Selector 2 Mode
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 10
Default 0 Units
Type 8 Bit User Save Update Rate Background read
Display Format Standard Decimal Places 0
Coding RW, TE
Value Text
0 Input 1
1 Input 2
2Add
3 Subtract
4 Multiply
5Divide
6 Time Const
7Ramp
8 Modulus
9 Powers
10 Sectional
K48 Variable Selector 2 Destination
Mode Open-Loop, RFC-A, RFC-S
Minimum A00 Maximum AB99
Default A00 Units
Type 16 Bit User Save Update Rate Drive reset read
Display Format Menu Param Alpha Numeric Decimal Places 3
Coding RW, DE, PT, BU
K49 Variable Selector 2 Source 1 Scaling
Mode Open-Loop, RFC-A, RFC-S
Minimum -4.000 Maximum 4.000
Default 1.000 Units
Type 16 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 3
Coding RW