384 E300 Design Guide
Issue Number: 1
See Variable Selector 1 Source 1 (K30).
See Variable Selector 1 Source 1 (K30).
See Variable Selector 1 Source 1 (K30).
K50 Variable Selector 2 Source 2 Scaling
Mode Open-Loop, RFC-A, RFC-S
Minimum -4.000 Maximum 4.000
Default 1.000 Units
Type 16 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 3
Coding RW
K51 Variable Selector 2 Control
Mode Open-Loop, RFC-A, RFC-S
Minimum 0.00 Maximum 100.00
Default 0.00 Units
Type 16 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 2
Coding RW
K52 Variable Selector 2 Enable
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 1
Default 1 Units
Type 1 Bit User Save Update Rate 4 ms read
Display Format Standard Decimal Places 0
Coding RW, BU