Media Card File Type (N04) shows the file type of the file selected with Media Card File Number (N03) as shown in the table below.
Media Card File Version (N05) shows the version number stored with the file selected with Media Card File Number (N03).
To set a file version number on a NV media card, the number required must be set in Media Card File Required Version (N11) and then the data must
be written to the NV media card. Failure to do this will result in no version number being displayed when selecting the NV media card file number in
Media Card File Number (N03).
Media Card File Checksum (N06) shows the checksum from the file selected with Media Card File Number (N03). If the media file is a Unidrive SP
SMARTCARD file, the checksum is (∑ All bytes except the checksum) modulo 65536. If the file was generated by a Unidrive M, a value of zero will be
displayed.
N04 Media Card File Type
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 6
Default Units
Type 8 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, Txt, ND, NC, PT
Value Text
0 None
1 Open-Loop
2RFC-A
3RFC-S
4 Not used
5User Prog
6 Option App
Media Card File Type (N04) File
0 No file selected
1 Open-loop mode parameter file
2 RFC-A mode parameter file
3 RFC-S mode parameter file
4 Not used
5 Onboard user program file
6 Option module applications file
N05 Media Card File Version
Mode Open-Loop, RFC-A, RFC-S
Minimum 0 Maximum 999
Default Units
Type 16 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT
N06 Media Card File Checksum
Mode Open-Loop, RFC-A, RFC-S
Minimum -2147483648 Maximum 2147483647
Default Units
Type 32 Bit Volatile Update Rate Background write
Display Format Standard Decimal Places 0
Coding RO, ND, NC, PT