Emerson Process Management GmbH & Co. OHG 9-41
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
10/2012
9
Modbus Commands
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address Tag Name
Data
Type
Client
Access
Description
Daniel Modicon
3310 3310 Setup.Calibration.SpanMethod5 Word R/W span cal method comp5 (0=Instant, 1=Stability)
3311 3311
Service.Calibration.ChanProc-
Mode1
Word R/W
cal proc mode comp1 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3312 3312
Service.Calibration.ChanProc-
Mode2
Word R/W
cal proc mode comp2 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3313 3313
Service.Calibration.ChanProc-
Mode3
Word R/W
cal proc mode comp3 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3314 3314
Service.Calibration.ChanProc-
Mode4
Word R/W
cal proc mode comp4 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3315 3315
Service.Calibration.ChanProc-
Mode5
Word R/W
cal proc mode comp5 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3316 3316 Service.Calibration.Tubing Word R/W Tubing (0=Parallel 1=Serial)
3397 3397
Setup.Communication.SIntMod-
busFt32
Word R/W Modbus 32Bit mode of serial COM
3398 3398
Setup.Communication.SSvcMod-
busFt32
Word R/W Modbus 32Bit mode of serial service COM
3399 3399
Setup.Communication.Eth2Mod-
busFt32
Word R/W Modbus 32Bit mode of Ethernet2
3400 3400
Setup.Communication.Eth1Mod-
busFt32
Word R/W Modbus 32Bit mode of Ethernet1
3401 3401
Service.Measurement.Compensa-
tion.ToffEnable1
Word R/W enable temperature zero compensation of comp1
3402 3402
Service.Measurement.Compensa-
tion.ToffEnable2
Word R/W enable temperature zero compensation of comp2
3403 3403
Service.Measurement.Compensa-
tion.ToffEnable3
Word R/W enable temperature zero compensation of comp3
3404 3404
Service.Measurement.Compensa-
tion.ToffEnable4
Word R/W enable temperature zero compensation of comp4
3405 3405
Service.Measurement.Compensa-
tion.ToffEnable5
Word R/W enable temperature zero compensation of comp5
3406 3406
Service.Measurement.Compensa-
tion.ToffSensorAssign1
Word R/W
assign temp-sensor of zero comp1 (0=None
1=DSP_T1 2=DSP_T2 etc.
3407 3407
Service.Measurement.Compensa-
tion.ToffSensorAssign2
Word R/W
assign temp-sensor of zero comp2 (0=None
1=DSP_T1 2=DSP_T2 etc.
3408 3408
Service.Measurement.Compensa-
tion.ToffSensorAssign3
Word R/W
assign temp-sensor of zero comp3 (0=None
1=DSP_T1 2=DSP_T2 etc.
3409 3409
Service.Measurement.Compensa-
tion.ToffSensorAssign4
Word R/W
assign temp-sensor of zero comp4 (0=None
1=DSP_T1 2=DSP_T2 etc.
3410 3410
Service.Measurement.Compensa-
tion.ToffSensorAssign5
Word R/W
assign temp-sensor of zero comp5 (0=None
1=DSP_T1 2=DSP_T2 etc.
3411 3411
Service.Measurement.Compensa-
tion.TfactEnable1
Word R/W enable temperature span compensation of comp1
3412 3412
Service.Measurement.Compensa-
tion.TfactEnable2
Word R/W enable temperature span compensation of comp2
3413 3413
Service.Measurement.Compensa-
tion.TfactEnable3
Word R/W enable temperature span compensation of comp3

Table of Contents