32 Applications Emotron AB 01-4429-01r2
6.1.3Mills
6.1.4 Mixers
Challenge Emotron VFX solution Menu
High start currents require larger fuses and cables.
Cause stress on equipment and higher energy cost.
Direct torque control reduces start current. Same
fuses can be used as those required for the
motor.
331-338, 350
Difficult to start with heavy load.
Possible to boost torque at start to overcome ini-
tial torque peak.
351–353
Material that could cause damage gets into the
mill.
Load Curve Protection quickly detects deviation.
Warning is sent or safety stop activated.
411–41C9
Process inefficiency due to broken or worn equip-
ment. Energy wasted and risk of process failure.
Load Curve Protection quickly detects deviation.
Warning is sent or safety stop activated.
411–41B, 41C1–41C9
Challenge Emotron VFX solution Menu
High start currents require larger fuses and cables.
Cause stress on equipment and higher energy cost.
Direct torque control reduces start current. Same
fuses can be used as those required for the
motor.
331-338, 350
Difficult to determine when mixing process is ready.
Built-in shaft power monitor determines when vis-
cosity is right.
411–41B
Process inefficiency due to e.g. a damaged or bro-
ken blade. Energy wasted and risk of process fail-
ure.
Load Curve Protection quickly detects deviation.
Warning is sent or safety stop activated.
411–41B, 41C1 –41C9