Cubemass DCI MODBUS RS485 Commissioning
Endress+Hauser 57
6.4.3 Current output: active/passive
The current output is configured as "active" or "passive" by means of various jumpers on the current
submodule.
#
Warning!
Risk of electric shock. Exposed components carry dangerous voltages.
Make sure that the power supply is switched off before you remove the cover of the electronics
compartment.
1. Switch off power supply.
2. Remove the I/O board ä 77.
3. Set the jumpers ( å 34).
"
Caution!
Risk of destroying the measuring device. Set the jumpers exactly as shown in å 34.
Incorrectly set jumpers can cause overcurrents that would destroy either the measuring device
or external devices connected to it.
4. Installation of the I/O board is the reverse of the removal procedure.
A0004411
Fig. 34: Configuring current output with the aid of jumpers (I/O board)
1 Current output
1.1 Active current output (default)
1.2 Passive current output
1.1
1.2
+
+
INPUT/OUTPUT 4
INPUT/OUTPUT 3
1
2
3
4
W
E
N
O
1
2
3
4
W
E
N
O
1
2
3
4
W
E
N
O
1
2
3
4
W
E
N
O