Cubemass DCI MODBUS RS485 Technical data
Endress+Hauser 93
10.1.11 Human interface
Display elements Liquid crystal display: illuminated, four lines with 16 characters per line
Selectable display of different measured values and status variables
3 totalizers
At ambient temperatures below –20 °C (–4 °F), the readability of the display may be impaired.
Operating elements Local operation with three optical sensors (S/O/ F)
Application specific Quick Setup menus for straightforward commissioning
Language groups Language groups available for operation in different countries:
Western Europe and America (WEA): English, German, Spanish, Italian, French, Dutch and
Portuguese
Eastern Europe/Scandinavia (EES): English, Russian, Polish, Norwegian, Finnish, Swedish, Czech
South and East Asia (SEA): English, Japanese, Indonesian
China (CN): English, Chinese
!
Note!
You can change the language group via the operating program FieldCare.
Remote operation Operation by means of MODBUS protocol.
10.1.12 Certificates and approvals
CE mark The measuring system is in conformity with the statutory requirements of the EC Directives.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
C-tick mark The measuring system meets the EMC requirements of the Australian Communications and Media
Authority (ACMA).
Ex approval Information about currently available Ex versions (ATEX, NEC/CEC etc.) can be supplied by your
Endress+Hauser representative on request. All explosion protection data are given in a separate
documentation, which is also available upon request ä 94.
Pressure device approval The measuring devices correspond to Article 3(3) of the EC Directive
97/23/EC (Pressure Equipment Directive) and have been designed and manufactured according to
good engineering practice.
Functional safety SIL 2: in accordance with IEC 61508/IEC 61511-1 (FDIS)
Other standards and
guidelines
EN 60529:
Degrees of protection provided by enclosures (IP code)
EN 61010-1:
Safety requirements for electrical equipment for measurement, control and laboratory use
IEC/EN 61326:
Electromagnetic compatibility (EMC requirements)
NAMUR Recommendation NE 21: Electromagnetic compatibility (EMC) of industrial process and
laboratory control equipment
NAMUR Recommendation NE 43:
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
NAMUR Recommendation NE 53:
Software of field devices and signal-processing devices with digital electronics