Proline Promass 83 PROFIBUS DP/PA Identification
Endress+Hauser 11
2 Identification
2.1 Device designation
The “Promass 80/83” flow measuring system consists of the following components:
Promass 80 or 83 transmitter
Promass F, Promass M, Promass E, Promass A, Promass H or Promass I sensor
Two versions are available:
Compact version: transmitter and sensor form a single mechanical unit.
Remote version: transmitter and sensor are installed separately.
2.1.1 Nameplate of the transmitter
a0002581
Fig. 2: Nameplate specifications for the “Promass 83” transmitter (example)
1 Order code / Serial number: See the specifications on the order confirmation for the meanings of the individual
letters and digits
2 Power supply / frequency: 20...55 V AC /16...62 V DC / 50...60 Hz
Power consumption: 15 VA / 15 W
3 F-CHIP option
4 Available inputs / outputs:
PROFIBUS DP
I-OUT: with current output
f–OUT: with pulse/frequency output
RELAY: with relay output
STATUS–IN: with status input
(auxiliary input)
5 Reserved for information on special products
6 Ambient temperature range
7 Degree of protection
PROMASS 83
ENDRESS+HAUSER
Order Code:
Ser.No.:
TAG No.:
16-62VDC/20-55VAC
50-60Hz
15VA/W
IP67/NEMA/Type4X83F25-XXXXXXXXXXXX
12345678901
ABCDEFGHJKLMNPQRST
–20°C (–4°F) < Tamb < +60°C (+140°F)
i
1
7
6
2
4
5
Pat. US 5,479,007
Pat. US 4,768,384
Pat. UK 261 435
5,648,616
4,801,897
EP 262 573
EP 618 680
PROFIBUS DP, STATUS-IN
RELAY, RELAY
3
BATCHING