Proline Promass 83 PROFIBUS DP/PA Technical data
Endress+Hauser 165
Pressure loss coefficient for Promass I
F06-8xIxxxxx-05-xx-xx-xx-000
Fig. 63: Pressure loss diagram for water
1Standard versions
2 Full bore versions (*)
DN d[m] K K1 K2
88.55 10
–3
8.1 10
6
3.9 10
7
129.95 10
4
15 11.38 10
–3
2.3 10
6
1.3 10
7
23.33 10
4
15
1)
17.07 10
–3
4.1 10
5
3.3 10
6
0.01 10
4
25 17.07 10
–3
4.1 10
5
3.3 10
6
5.89 10
4
25
1)
25.60 10
–3
7.8 10
4
8.5 10
5
0.11 10
4
40 25.60 10
–3
7.8 10
4
8.5 10
4
1.19 10
4
40
1)
35.62 10
–3
1.3 10
4
2.0 10
4
0.08 10
4
50 35.62 10
–3
1.3 10
4
2.0 10
4
0.25 10
4
Pressure loss data includes interface between measuring tube and piping
1)
DN 15, 25, 40 “FB” = Full bore versions of Promass l
1000
100
10
1
0.1
0.01 0.1
1
10 100
DN 40
DN 25 *
DN 50
DN 40 *
DN 25
DN 15 *
DN 15
[mbar]
[t/h]