iPAK2 User Guide
20
2.4.5. Roll-spot
Pre-heat = 0, Cool1 = 0, Upslope = 0, Downslope = 0, Post-heat = 0,
Pulsations = 1, Force profile = off.
WAVO/P
ForceO/P
Current
Presqueeze
Squeeze
Hold
STARTI/P
Mainheat
Off
Hold
Off
Squeeze
Hold
Squeeze
Mainheat
Mainheat
MOTORO/P
To use Roll-Spot, set Seam welding in configuration, then select the
Roll-Spot option in the weld program.
Extended