Section 14: In Case of Difficulty
175
Problem: Table does not maintain a consistent level with the carriage. A
symptom of this problem is that the depth of engraving starts out uniform and
correct, but then varies either on the right side or at the bottom.
Solution:
¾ At the home position, put on your focus gauge and manually raise the table (“Focus” key
and rotate knob clockwise) to where it just touches the gauge. Shut off the machine and
with your hand, move the carriage to each of the other three corners of the table. The
focus gauge should just touch each of the corners as it did in the starting (home) position.
If there is a variance, the table needs to be adjusted. Contact Epilog Technical support
for the correct procedure.